Alkaline Battery, 23A
4. Electrical Characteristics:
Unless otherwise stated, all measurements are to be performed at a Standard
Environment of
20 ± 2°C
55± 20%RH.
All samples are normalized for 8 hours at least at the above environment prior to measurement.
The digital voltmeter (DCM) is with the precision of 1mV (internal resistance not less than 1 Megohm). The load resistance
of the total circuit is accurate within ±0.5% of the specified value.
4.1 Open circuit voltage:
/
OCV(V)
Initial ≥12.0
4.2 Service output:
Load
10KΩ
Test mode
24h/d
end voltage
6.0V
Initial (MAD) ≥52 h
the delayed discharge performance stored 12 months is above 90% of initial
m: minute h: hour d: day
*The initial discharge test shall commence within 30 days of manufacture. During stored period, the cells shall be stored under
20±2,RH55±20% conditions.
5. Expiry Date:
1 year
6. Expiry Date Marking:
6.1 Unless
otherwise specified, each battery will carry a manufacturing date code followed by month and year of
manufacturing for domestic and manufacturing date code followed by month and year of expiry for export. (Shelf life 1
year)
7. Packaging Requirements:
7.1 The total of heavy metal lead, cadmium, mercury, and hexavalent chromium concentration shall not exceed
100 ppm in Packaging materials and printing inks. Ozone depleting substances (ODS) shall not be used in the
manufacturing of any packaging.
The printing on each cell label is legible and permanent. Label defects, if any, shall conform to mutually agreed
upon limit samples.
7.2 Otherwise packaging for shipment and sales shall conform to the mutually agreed to Packaging Specification of
the designated customers.
Distrelec Schweiz AG, Grabenstrasse 6, 8606 Nänikon, Switzerland, T +41 44 944 99 11, info@distrelec.com, distrelec.com