Datasheet
5. Leakage Resistance
5.1 Overdischarge 
Test conditions:test battery(B1) shall be predischarged to 50 % depth of discharge. It shall 
then be connected in series with three undischarged additional single cell 
batteries(B2,B3,B4) of the same type. A resistive load R1(3.9Ω)connected   
in series with the assembly of batteries , R1 is 3.9 The test shall be continued 
for 24 h. 
Number of test samples:9 batteries 
Requirement:no explosion and no fire during this test. 
5.2 High temperature leakage test 
Test conditions:store 20 days under 60±2℃,then store 4~24h under standard environment。 
Number of test samples:24 batteries 
Requirement:No visible leakage;No explosion. 
6. Security Characteristics
6.1 User Drop Test 
This test simulates the situation when a battery is accidentally dropped.   
Test  conditions:  Undischarged  test  batteries  shall  be  dropped  from  a  height  of  1  m  onto  a 
concrete surface. Each test battery shall be dropped six times, twice in each of 
the three axes. The test batteries shall be stored for 1 h afterwards. 
Number of test sets: 5 batteries 
Requirement: No fire, No explosion. 
6.2 Short-circuit explosion-proof characteristics 
This test simulates an external short circuit of a battery during daily handling of batteries. 
Test conditions: Positive and negative terminals of an undischarged battery shall be connected 
directly.  The  circuit  shall  be  completed  for  24  h  or  until  the  battery  case 
temperature  has  returned  to  ambient.  The  resistance  of  the  inter-connecting 
circuitry shall not exceed 0,1 Ω. 
Number of test samples: 5 batteries 
Requirement: No fire or explosion; Leakage is allowable. 
6.3 Incorrect installation 
This test simulates incorrect installation of a battery in a series application. 
Test  conditions:  4  undischarged  batteries  are  used  per  test.  3  batteries  are  placed  correctly 
inseries;  the  4
th
  battery  is  reversed  with  respect  to  polarity.  The  circuit  is
maintained until venting occurs or the reversed battery temperature has returned 
to ambient. 
Number of test sets: 5 (20 batteries) 
Requirement: No fire or explosion; Leakage is allowable. 
Distrelec Schweiz AG, Grabenstrasse 6, 8606 Nänikon, Switzerland, T +41 44 944 99 11, info@distrelec.com, distrelec.com






