Datasheet

4. Electrical Characteristics
Unless otherwise stated, all measurements are to be performed at a
Standard Environment of 23 ±C
55
± 20% RH
.
A
ll samples are normalized for 8 hours at least at the above environment prior to measurement.
The digital voltmeter (DCM) is with the precision of 1mV (internal resistance not less than 1 Megohm).
The load resistance of the total circuit is accurate within ±0.5% of the specified value.
4.1 Open circuit voltage and closed circuit voltage (Load resistance 50Ω, 0.1~0.5S)
/
OCV(V) CCV(V)
Initial
1.70 1.62
Stored 1 year
1.70 1.62
4.2 Service output
Load
600mA 1.2 W/0.65 W 400 mW 50 mA
Test mode
24h/d
2s/28s
5 m/h
24 h/d
4 m/15 m
8 h/d
1h/12h,
24h/d
End voltage
0.9V 1.05 V 1.0 V 0.9 V
Unit min pulse min h
Applications
Reference
Digital still
camera
High intensity lighting Digital Audio
Initial
Normal
115 170 240 25
MAD
80 120 140 18.6
Stored 1 year
Normal
105 140 220 24
MAD
60 100 120 18
m: minute h: hour d: day
Remark: 1) The initial discharge test shall commence within 30 days of manufacture. During stored period, the cells
shall be stored under 20±2, RH 55±20% conditions.
2) - The batteries shall not leak during the service life test before the end voltage reached.
3) MAD
minimum average duration--
our guarantee discharge value.
4)Norm
alnormal data, it's our normal daily value, battereis dicharge value are on this as base to be upper or
lower.
Distrelec Schweiz AG, Grabenstrasse 6, 8606 Nänikon, Switzerland, T +41 44 944 99 11, info@distrelec.com, distrelec.com