Datasheet
5. Leakage Resistance
5.1 Overdischarge
Test conditions:test battery(B1) shall be predischarged to 50 % depth of discharge. It shall
then be connected in series with three undischarged additional single cell
batteries(B2,B3,B4) of the same type. A resistive load R1(3.9Ω)connected
in series with the assembly of batteries , R1 is 3.9 The test shall be continued
for 24 h.
Number of test samples:9 batteries
Requirement:no explosion and no fire during this test.
5.2 High temperature leakage test
Test conditions:store 20 days under 60±2℃,then store 4~24h under standard environment。
Number of test samples:24 batteries
Requirement:No visible leakage;No explosion.
6. Security Characteristics
6.1 User Drop Test
This test simulates the situation when a battery is accidentally dropped.
Test conditions: Undischarged test batteries shall be dropped from a height of 1 m onto a
concrete surface. Each test battery shall be dropped six times, twice in each of
the three axes. The test batteries shall be stored for 1 h afterwards.
Number of test sets: 5 batteries
Requirement: No fire, No explosion.
6.2 Short-circuit explosion-proof characteristics
This test simulates an external short circuit of a battery during daily handling of batteries.
Test conditions: Positive and negative terminals of an undischarged battery shall be connected
directly. The circuit shall be completed for 24 h or until the battery case
temperature has returned to ambient. The resistance of the inter-connecting
circuitry shall not exceed 0,1 Ω.
Number of test samples: 5 batteries
Requirement: No fire or explosion; Leakage is allowable.
6.3 Incorrect installation
This test simulates incorrect installation of a battery in a series application.
Test conditions: 4 undischarged batteries are used per test. 3 batteries are placed correctly
inseries; the 4
th
battery is reversed with respect to polarity. The circuit is
maintained until venting occurs or the reversed battery temperature has returned
to ambient.
Number of test sets: 5 (20 batteries)
Requirement: No fire or explosion; Leakage is allowable.