Datasheet

5. Leakage Resistance
5.1 Overdischarge
Test conditionstest battery(B1) shall be predischarged to 50 % depth of discharge. It shall
then be connected in series with three undischarged additional single cell
batteries(B2,B3,B4) of the same type. A resistive load R1(3.9Ωconnected
in series with the assembly of batteries , R1 is 3.9 The test shall be continued
for 24 h.
Number of test samples9 batteries
Requirementno explosion and no fire during this test.
5.2 High temperature leakage test
Test conditionsstore 20 days under 60±2℃,then store 4~24h under standard environment
Number of test samples24 batteries
RequirementNo visible leakageNo explosion.
6. Security Characteristics
6.1 User Drop Test
This test simulates the situation when a battery is accidentally dropped.
Test conditions: Undischarged test batteries shall be dropped from a height of 1 m onto a
concrete surface. Each test battery shall be dropped six times, twice in each of
the three axes. The test batteries shall be stored for 1 h afterwards.
Number of test sets: 5 batteries
Requirement: No fire, No explosion.
6.2 Short-circuit explosion-proof characteristics
This test simulates an external short circuit of a battery during daily handling of batteries.
Test conditions: Positive and negative terminals of an undischarged battery shall be connected
directly. The circuit shall be completed for 24 h or until the battery case
temperature has returned to ambient. The resistance of the inter-connecting
circuitry shall not exceed 0,1 Ω.
Number of test samples: 5 batteries
Requirement: No fire or explosion; Leakage is allowable.
6.3 Incorrect installation
This test simulates incorrect installation of a battery in a series application.
Test conditions: 4 undischarged batteries are used per test. 3 batteries are placed correctly
inseries; the 4
th
battery is reversed with respect to polarity. The circuit is
maintained until venting occurs or the reversed battery temperature has returned
to ambient.
Number of test sets: 5 (20 batteries)
Requirement: No fire or explosion; Leakage is allowable.
Distrelec Schweiz AG, Grabenstrasse 6, 8606 Nänikon, Switzerland, T +41 44 944 99 11, info@distrelec.com, distrelec.com