Datasheet

4. Electrical Characteristics
Unless otherwise stated, all measurements are to be performed at a
Standard Environment of 20 ±C
55 ± 20% RH.
All samples are normalized for 8 hours at least at the above environment prior to measurement.
The digital voltmeter (DCM) is with the precision of 1mV (internal resistance not less than 1 Megohm).
The load resistance of the total circuit is accurate within ±0.5% of the specified value.
4.1 Open circuit voltage and closed circuit voltage (Load resistance 3.9Ω, 0.3S)
/
OCV(V) CCV(V) S.C.(A) (reference)
Initial
Min 1.57 1.40 6.0
Normal 1.60 1.45 8.0
Stored 1 year
Min 1.55 1.37 4.5
Normal 1.57 1.40 6.0
4.2 Service output
Load
20Ω 600mA 600mA 5.1Ω 5.1Ω 100mA 24Ω 75Ω 50 mA,
Test mode
24h/d 24h/d
10s/m,
1h/d
1h/d 4m/h,8h/d 1h/d
15s/m
8h/d
4h/d
1h/12h
24h/d
End voltage
0.9V 0.9V 0.9V 0.8V 0.9V 0.9V 1.0v 0.9V 0.9 V
Unit h m pulse m m h h h h
Applications Reference Reference
Photo
flash
Toy
Portable
lighting
Digital
audio
Remote
control
Radio/
Clock
Digital
Audio
Initial
MAD 17.5 32 300 235 220 8.8 19.5 71 20.5
Normal 18.5 40 380 260 240 9.8 20.7 75 22
Stored
1 year
MAD 16.4 27 270 220 200 8.6 19.0 68 18.5
Normal 17.5 32 320 240 225 9.3 20.0 72 20
m: minute h: hour d: day
Remark: 1) The initial discharge test shall commence within 30 days of manufacture. During stored period, the cells
shall be stored under 20±2, RH 55±20% conditions.
2) Lot release service output test is conducted by 20Ω continuous discharging to 0.9volts
- The batteries shall not leak during the service life test before the end voltage reached.
3) MADminimum average duration--our guarantee discharge value.
4)Normalnormal data, it's our normal daily value, battereis dicharge value are on this as base to be upper or
lower.
Distrelec Schweiz AG, Grabenstrasse 6, 8606 Nänikon, Switzerland, T +41 44 944 99 11, info@distrelec.com, distrelec.com