Datasheet
4. Electrical Characteristics
Unless otherwise stated, all measurements are to be performed at a
Standard Environment of 20 ± 2°C
55 ± 20% RH.
All samples are normalized for 8 hours at least at the above environment prior to measurement.
The digital voltmeter (DCM) is with the precision of 1mV (internal resistance not less than 1 Megohm).
The load resistance of the total circuit is accurate within ±0.5% of the specified value.
4.1 Open circuit voltage and closed circuit voltage (Load resistance 3.9Ω, 0.3S)
/
OCV(V) CCV(V) S.C.(A) (reference)
Initial
Min 1.57 1.40 6.0
Normal 1.60 1.45 8.0
Stored 1 year
Min 1.55 1.37 4.5
Normal 1.57 1.40 6.0
4.2 Service output
Load
20Ω 600mA 600mA 5.1Ω 5.1Ω 100mA 24Ω 75Ω 50 mA,
Test mode
24h/d 24h/d
10s/m,
1h/d
1h/d 4m/h,8h/d 1h/d
15s/m
8h/d
4h/d
1h/12h
24h/d
End voltage
0.9V 0.9V 0.9V 0.8V 0.9V 0.9V 1.0v 0.9V 0.9 V
Unit h m pulse m m h h h h
Applications Reference Reference
Photo
flash
Toy
Portable
lighting
Digital
audio
Remote
control
Radio/
Clock
Digital
Audio
Initial
MAD 17.5 32 300 235 220 8.8 19.5 71 20.5
Normal 18.5 40 380 260 240 9.8 20.7 75 22
Stored
1 year
MAD 16.4 27 270 220 200 8.6 19.0 68 18.5
Normal 17.5 32 320 240 225 9.3 20.0 72 20
m: minute h: hour d: day
Remark: 1) The initial discharge test shall commence within 30 days of manufacture. During stored period, the cells
shall be stored under 20±2℃, RH 55±20% conditions.
2) Lot release service output test is conducted by 20Ω continuous discharging to 0.9volts
- The batteries shall not leak during the service life test before the end voltage reached.
3) MAD:minimum average duration--our guarantee discharge value.
4)Normal:normal data, it's our normal daily value, battereis dicharge value are on this as base to be upper or
lower.