PERFORMANCE PROPERTIES CHEMICAL RESISTANCE
Finished products are laminated to
aluminium panels and allowed to dwell for 24 hours prior to testing. Test conducted at room
temperature. Testing consisting of five cycles of 10 min immersions in the specified test fluid, followed by 30 min recovery periods. After final
immersion, samples rubbed 10 times with cotton swab saturated with test fluid.
CHEMICAL REAGENT SUBJECTIVE OBSERVATION OF VISUAL CHANGE
LABEL STOCK SUBSTRATE /
ADHESIVE
PRINTING AFTER IMMERSION AND
COTTON SWAB RUBS
Petroleumether 80/110 No visible effect No visible effect
Mineral oil No visible effect No visible effect
Toluene Slight adhesive oozing No visible effect
Alcohol Mixture* No visible effect No visible effect
Methyl ethyl ketone Slight adhesive oozing No visible effect
1,1,1-Trichloroethane Slight adhesive oozing No visible effect
5 % Sodium hydroxide No visible effect No visible effect
5 % Sodium chloride No visible effect No visible effect
5 % Sulfide acid No visible effect No visible effect
Skydrol® 500B-4 No visible effect No visible effect
2% soft soap No visible effect No visible effect
Water No visible effect No visible effect
* - Alcohol mixture is a mixture of 50% ethanol, 30% methanol and 20% distilled water
Product testing, customer feedback, and history of similar products, support a customer performance expectation of at least two years from
the date of receipt for this product as long as this product is stored in its original packaging in an environment below 80°F (27°C) and 60% RH.
We are confident that our product will perform well beyond this time frame. However, it remains the responsibility of the user to assess the
risk of using such product. We encourage customers to develop functional testing protocols that will qualify a product's fitness for use in their
actual applications.
Trademarks
Polyken™ is a trademark of Testing Machines Inc.
Skydrol® is a registered trademark of the Monsanto Company
ASTM: American Society for Testing and Materials (U.S.A.)
PSTC: Pressure Sensitive Tape Council (U.S.A.)
Notes
All values shown are averages and should not be used for specification purposes.
Test data and test results contained in this document are for general information only and shall not be relied upon by RND customers for
designs and specifications, or be relied on as meeting specified performance criteria. Customers desiring to develop specifications or
performance criteria for specific product applications should contact RND for further information
Product compliance information is based upon information provided by suppliers of the raw materials used by RND to manufacture this
product or based on results of testing using recognized analytical methods performed by a third party, independent laboratory. As such, RND
makes no independent representations or warranties, express or implied, and assumes no liability in connection with the use of this
information