User Manual
15
Lo
w-pass Filter
Range Resoluon
300.0 A 0.1 A
Inrush Current
Integraon Time: 100ms.
Trigger Current: 5.0A.
VoltSense: 80V ~ 600V AC (At the p of clamp).
Cut-o Frequency (-3dB): Approx. 160Hz.
Aenuaon Characterisc: Approx. -24dB / Oct.
The proprietary informaon in this manual is protected by copyrights. Any photocopies,
reproducons or translaon to another language are not allowed unless it is permied.
And all rights are reserved.
The informaon in this manual is corre ct when prinng. However, RND will connuously
improve products and reserve the rights to change specicaons, equipment, and
maintenance procedures at any me without noce.
Range Resoluon Accuracy(50Hz/60Hz)
60.00 A 0.01 A ± (3.5% + 25d)
300.0 A 0.1 A ± (3.5% + 5d)