User Manual

9
Technical Data
Voltage range : 100V AC~1000V AC.
Frequency: 45~65 Hz.
Sensivity: 3mm distance from wire carrying 100 VAC.
Polluon Degree: 2
Altude: Up to 2000 meter.
Temperature range: 0 ~50°C
Humidity: <80%.
Power supply: 2x AAA, 1.5 V LR03.
Dimensions (W x H x D): 152mm x 22mm x 18mm.
Weight: Approx. 40g (including baery)
Over voltage category: CAT III 1000VAC,CAT IV 600VAC.
CAT Applicaon eld
I The circuits not connected to mains.
II The circuits directly connected to Low-voltage installaon.
III The building installaon.
IV The source of the Low-voltage installaon.
The proprietary informaon in this manual is protected by copyrights. Any photocopies, reproducons
or translaon to another language are not allowed unless it is permied. And all rights are reserved.
The informaon in this manual is corre ct when prinng. However, RND will connuously improve products
and reserve the rights to change specicaons, equipment, and maintenance procedures at any me