User Manual

3
WARNING
This instrucon manual contains both informaon and warnings that are necessary for the
safe opera-on and maintenance of the instrument. It is recommended that you read the
manual carefully and ensure that its contents are fully understood. Failure to understand
these instrucons and to comply with the warnings and instrucons contained herein can
result in serious injury or damage.
The unit is indicated by a short illuminaon of the red LED in the p of the detector and
a short beep.
The working frequency of the red LED and the buzzer are the same, and it is decided by
the electric eld which detected from detector. The higher electric eld is sensed, the
higher frequency indicates (1~10Hz).
Contact-free voltage detecon 100 VAC~1000 VAC.
Contact-free detecon of AC voltage on (insulated) cables and conductors.
Locang line interrupons in (insulated) cables and conduct-ors. Phase tester of sockets.
Phase determinaon of (3 phase) AC lines, mul core cable and wall sockets.
Features
Safety Measures
The instrument has le our factory in a safe and perfect condion. To maintain this con-
dion, the user must pay aenon to the safety references contained in this in-strucon
manual.
WARNING
Only touch the instrument handle for any voltage detecon. Do not touch the p of the
instrument while tesng.
WARNING
The instrument may only be used within operang ranges as specied in the technical data
secon.