User Manual

22 :OCP
Output all steps in OCP mode
:OCP 10V,5S,3A,
0.1A,0.1A,0.2S,2A,2V,1.5A,0.9
A,5
This command means: VON
voltage is 10V, VON delays
5s, current range is 3A.
Initial current is 0.1A,
stepping current 0.1A,
stepping delay 0.2s, cutoff
current 2A, OCP voltage 2V,
max overcurrent 1.5A and min
0.9A, which save in LIST 5.
no
23 :RCL:OCP
1-10
Recall/query the OCP's unit. Recall the
query unit before query and then use the
query.
:RCL:OCP 2
Recall the OCP mode and save
in LIST 2.
:RCL:OCP?
>10V,5S,3A,
0.1A,0.1A,0.2S,2A,2V,1
.5A,0.9A,2
Query the value of OCP