User Manual

Safety Symbols
These safety symbols may appear in this manual or on the series.
WARNING
DANGER High Voltage
Earth (ground) Terminal
AC Input
• AC Inut Voltage: 230 V, 50 Hz
• ConnecttheprotecvegroundingconductoroftheACpowercord
toanearthground,toavoidelectricalshock.
Operaon Environment
• Locaon:Indoor,nodirectsunlight,dustfree,almostnon-conducve
polluon(notebelow)
• RelaveHumidity:<80%
• Altude:<2000m
• Temperature: 32 – 104 F/0 – 40 °C
Storage environment
• Locaon:Indoor
• RelaveHumidity:<70%
• Temperature:14–158F/-10–70°C
Fuse
• Toensurereprotecon,replacethefuseonlywiththespeciedtype
andrang.
• Disconnectthepowercordbeforefusereplacement.
• Makesurethecauseoffuseblowoutisxedbeforefusereplacement.
ENGLISH
SAFETY
Please read this guide before operang this equipment
Intended use of RND laboratory power supplies
ThelaboratorypowersupplyisintendedtosupplyDCpowerupto30VDCand
5A.Loadsthatarehigherthanthemaximumvaluespermiedbythepower
supplymustnotbeconnected.Thepowersupplymayonlybeusedinadry,
dust-freeenvironmentwithadequatevenlaon.Onlyforuseindryindoor
areas!Thepowersupplymustnotbeusedinenvironmentswherethereisa
riskofexplosion.Failuretoadheretothesecondionsortoobservethesafety
instruconsmayresultinaccidentsordamage.Anyuseotherthanthat
describedinthisinstruconmanualisnotpermiedandwillleadtolossof
warrantyandguaranteeandtoexclusionofliability.Thisalsoappliestochanges
andmodicaons.
Safety, service and operang instrucons
• Thisdeviceisnotintendedtobeusedbypersons(includingchildren)with
reducedphysical,sensoryormentalcapabilies,orwithalackofexperience
and/orknowledge,unlesstheyaresupervisedbyapersonresponsible
fortheirsafetyorunlesstheyhavebeeninstructedontheuseofthedevice
by this person
• Donottouchoroperatethedevicewithwethands
• Beforereplacingfaultyfuses,alwayseliminatethecauseofthefault!
Onlyusethefusesindicated
• Onlyconnectthedevicetoanoutletwithanearthwire
• Alwaysmakesurethatthereisadequatevenlaon.Nevercovertheairinlets
• Avoidsevereimpactsorroughhandlingthatleadstodamage.
• Donotdischargestacelectricity.
• Neveropentheenclosure!Intheeventoffaults,malfuncons,mechanical
damageoroperangproblemsthatcannotberesolvedusingthisinstrucon
manual,takethedeviceoutofoperaonimmediatelyandconsultourService
departmentforadviceorrepairs.Observetheservicenocesregarding
serviceproceduresandtechnicaladvice.Thesecanbefoundinourterms
andcondionsorpublicaons.