Datasheet
True RMS Multimeter
RND 355-00003
RND is a trademark of Distrelec
Features
Specifications
• 6,000 count digital and 60 segments analog display
• Large white LED backlight display
• True RMS measurements on ACV
• LoZ for prevent false reading from ghost voltage
• AutoVolt automatic AC/DC voltage selection
• Auto Ranging
• 0.5% DCV accuracy
• Smart Hold
• Peak Hold for capture peak readings
• Relative Function
• Auto Power Off (can be disabled)
• Capacitance measurements
• Frequency Counter on ACV
• Diode Test
• °C/°F Temperature Function
• AC/DC μA Function
• Temperature Probe included
• VoltSeekTM for non-contact voltage detection
• EasyStickTM holster with built in magnetic sticker
• ContiVisionTM for visible continuity beeper
• Battery Capacity indication in segments
• Included Holster with Probe Holder, Tilt Stand and Magnetic sticker
• CAT IV 600V/ CATIII 1000V standard
Maximum voltage applied to any terminal:
1000 Vac rms or 1000 Vdc. rms
Display : 6000 counts.
Polarity Indication : Automatic, positive implied, negative indicated.
Overrange Indication : OL
Batteries Life : 200 hours ALKALINE Battery
Low Batteries Indication : Voltage drops below operating voltage will flash.
Power Requirement : 9V battery
Auto Power Off : 20 minutes.
Operating Temperature : -10 ~10°C
1
0°C ~ 30°C (<80% RH),
30°C ~ 40°C (<75% RH),
40°C ~ 50°C (<45%RH)
Storage Temperature :
-40°C to 60°C , 0 to 80% R.H. (baeries not ed)
Measure : Samples 3 mes per second.
Altude : 6561.7 (2000m)
Weight : 250g (including battery)
Dimensions (W x H x D) :
74mm x 156mm x 44mm.
Pollution degree : 2
Safety : Complies with EN61010-1,CAT.IV. 600V, CAT|||. 1000V
EMC
: EN 61326-1
Shock vibration : Sinusoidal vibration per MIL-PRF- 28800F (5 ~ 55 Hz, 3g max.)
Drop Protection : 4 feet drop to hardwood on concrete floor.
Indoor Use.
I The circuits not connected to mains.
II The circuits directly connected to Low-voltage installation.
III The building installation.
IV The source of the Low-voltage installation.
CAT Appli
caon eld