Datasheet
AC+DC True RMS
Industrial Multimeter
RND 355-00002
RND is a trademark of Distrelec
Features
• 6000 count digital display.
• 62 segment bar graph .
• Extra Large scale display and white backlit
• True RMS
• 0.08% basic DCV accuracy
• Automatic AC/DC Voltage detect with low impedance (Auto-V LoZ)
• VoltSeek (Non-Contact Voltage detect)
• Smart Data Hold
• Peak Hold (1ms)
• Min/Max function
• AC+DC function
• Frequency Counter on AC mode
• Capacitance Measurement
• Temperature
• Low battery indicator with segments
• Auto Power Off (20 minutes)
• Shock proof from 4 feet drops
• CAT.IV 600V/CAT. III 1000V Safety standard
Specifications
Maximum voltage applied to any terminal: 1000 V
ac
rms or 1000 V
dc.
rms
Display: 6000 counts.
Polarity Indication: Automatic, positive implied, negative indicated.
Overrange Indication: OL
Batteries Life: 200hours ALKALINE Battery (No Backlight)
Low Batteries Indication: Voltage drops below operating voltage, will flash.
Power Requirement: 9V battery
Auto Power Off: 20 minutes.
Operating Temperature: -10 ~10°C
10°C ~ 30°C (≤80% RH),
30°C ~ 40°C (≤75% RH),
40°C ~ 50°C (≤45%RH)
Storage Temperature:
-20°C to 60°C, 0 to 80% R.H. (baeries not ed)
Temperature Coecient:
0.15 x (Spec.Accy) / °C, < 18°C or > 28°C .
Measure: Samples 3 mes per second .
Altude: 6561.7 (2000m)
Safety: Complies with EN61010
CAT.IV. 600V, CAT.III. 1000V
CAT Applicaon eld
I The circuits not connected to mains.
II The circuits directly connected to Low-voltage installaon.
III The building installaon.
IV The source of the Low-voltage installaon.
Weight: 460g (including battery)
Dimensions (W x H x D): 94mm x 190mm x 48mm with holster. Accessories:
Battery (installed), Test leads and user manual.
(The probe assembly provided with the product are for use with this product)
Pollution degree: 2
EMC: EN 61326-1
Shock vibration: Sinusoidal vibration per MIL-PRF- 28800F (5 ~ 55 Hz, 3g max.)
Drop Protection: 4 feet drop to hardwood on concrete floor.
Indoor
Use.