Datasheet

RND is a trademark of Distrelec
Features
Peltier Element
Specification
Hot Side Temperature
25 °C
Qmax 118 W
Imax 12.5 A
Vmax
15.4 V
Module Resistance 910 mOhm
Delta Tmax 67 °C
50 °C
128 W
12.5 A
16.3 V
1.03 Ohm
75 °C
Performance Curves Th=27 °C
Performance Curves Th=50
°C
Tolerances for thermal and electrical parameters ± 10%
The Thermoelectric modules utilise the Peltier phenomenon principle to pump heat
when voltage is applied
When supplied with a suitable electric current, they can either cool or heat
Suited for cooling miniature electronic components such as infra-red detector chips,
microwave IC's, fibre-optic lasers and detectors
Solid-state long term stability

Summary of content (2 pages)