Datasheet
RND is a trademark of Distrelec
Brushless DC Axial Fan
198 ... 242 V
Starting Voltage 175 V
Operating Temperature
-10 ... 70℃
Storage Temperature
-20 ... 80℃
Insulated Type
Class B(130℃)
Safety Standard
CCC, CE, TUV
Locked Current 80 mA
Operating Voltage
Characteristics
Drawing
Impedance Protected
Noise Level 30.8 dBA (33.8 max.)
Insulation Resistance 10 MΩ @ 500 VDC
Dielectric Strength
2000 VAC / 1mA for 1 min.
Service Life 50000 hours
Tensile Strength of Connector
1 kg for 15 sec.
Environment Humidity
10 %(RH)45℃ for 24 hours & 98% (RH) 45℃ for 24 hours
Motor Protection
Art Nr.