Datasheet
6. Environment Test Method
NO.  ITEM  TEST CONDITION AND REQUIREMENT 
1 
High Temperature Test 
(Storage) 
After being placed in a chamber with 802ºC for 96 hours and then being placed in 
normal condition for 2 hours. 
Allowable variation of SPL after test: 10dB. 
2 
Low Temperature Test 
(Storage) 
After  being  Placed  in  a  chamber  with  -302ºC  for  96  hours  and  then being placed 
in normal condition for 2 hours. 
Allowable variation of SPL after test: 10dB. 
3  Humidity Test 
After being Placed in a chamber with 90-95%  R.H. at  402ºC for 96 hours and then 
being placed in normal condition for 2 hours. Allowable variation of SPL after test: 
10dB. 
4 
Temperature 
Cycle 
Test 
The part shall be subjected to 5 cycles. One cycle shall be consist of: 
Allowable variation of SPL after test: 10dB. 
5  Drop Test 
Drop on a hard wood board of 4cm thick, any directions ,6 times, at  the  height  of 
100cm.  Allowable  variation  of  SPL  after  test:  10dB. 
6  Vibration Test 
After  being  applied  vibration  of  amplitude  of  1.5mm  with  10  to  55  Hz band  of 
vibration  frequency  to  each  of  3  perpendicular  directions  for  2  hours. 
Allowable variation of SPL after test: 10dB. 
7 
Solder ability Test 
Lead terminals are immersed in rosin for 5 seconds and then immersed  in  solder  bath 
of  +3005ºC  for  31  seconds.90%  min.  lead  terminals  shall  be  wet  with  solder 
(Except  the  edge  of  terminals). 
8 
Terminal / Wire 
Strength Pulling Test 
The  force  of  9.8N(1.0kg)  is  applied  to  each  terminal  in  axial direction for 10 
seconds. No visible damage and cutting off. 
7. Reliability Test
Continuous life test: 
250 Hours continuous operating at +70 ºC with maximum rated voltage applied . Intermittent life test: 
Aduty cycle of 1 minute on, 5 minutes off,a minimum of 10000 times at temperature +25 ºC2 
- 30ºC 
+80ºC 
+25ºC  +25ºC 
Distrelec Schweiz AG, Grabenstrasse 6, 8606 Nänikon, Switzerland, T +41 44 944 99 11, info@distrelec.com, distrelec.com