Datasheet

TEST REPORT
# dB mA Hz
1 101 6.0 3574
2 100 6.0 3627
3 103 6.2 3874
4 105 5.1 3822
5 105 5.5 3715
Remark:
(1)Sound Press Level
90dB at 30cm / 12VDC
(2)Consumption Current20mA at 12VDC
(3)Resonate Frequency3400Hz500
6.
Environment Test Method
NO. ITEM TEST CONDITION AND REQUIREMENT
1
High Temperature Test
(Storage)
After being placed in a chamber with 802ºC for 96 hours and then being placed in
normal condition for 2 hours.
Allowable variation of SPL after test: 10dB.
2
Low Temperature Test
(Storage)
After being Placed in a chamber with -302ºC for 96 hours and then being placed
in normal condition for 2 hours.
Allowable variation of SPL after test: 10dB.
3 Humidity Test
After being Placed in a chamber with 90-95% R.H. at 402ºC for 96 hours and then
being placed in normal condition for 2 hours. Allowable variation of SPL after test:
10dB.
4
Temperature
Cycle
Test
The part shall be subjected to 5 cycles. One cycle shall be consist of
Allowable variation of
SPL after test: 10dB.
- 30ºC
+80ºC
+25ºC +25ºC
Distrelec Schweiz AG, Grabenstrasse 6, 8606 Nänikon, Switzerland, T +41 44 944 99 11, info@distrelec.com, distrelec.com