Datasheet

Initial Contact Resistance
Contact Material
Max.Switching Power
Max.switching Voltage
Max.switching Current
100m
Silver alloy
277 VAC
12 A
Insulation Resistance
Operate time
Release time
Shock Resistance
Vibration Resistance
Weight
Construction
1.
00M
min (at 500VDC)
15ms
10 ms
110 m/s
2
11ms
10~55Hz
amplitude 1.5mm
Sealed & Dust Cover
10-13.5 g
Dielectric Streng
th:
Between coil and Contacts:
Between open contacts:
50Hz 5000V
50Hz 1000V
3324 VA
Life expectancy (mechanical)
Life expectancy (electrical)
10 000 000 operations
(frequency 18 000 op/h
100 000 operations
(frequency 1200 op/h
CONTACT DATA:
OPERATION CONDITIONS: