Datasheet
Aluminum Electrolytic Capacitors
1. Scope:
This specification applies to aluminium electrolytic capacitor , used in electronic equipment.
2. Electrical charateristics:
NO. ITEM
2. 1
Rated voltage
2. 2
Capacitance
2. 3
1. Measuring frequency :  120 ± 12Hz
2. Measuring voltage : ≦0.5Vrms + 0.5 ~ 2.0VDC
Voltage range
﹑capacitance 
range, see specification of  this 
series.
Dissipation factor
〔 〕
3. Measurement 
circuit :
2. 4
Leakage current  DC leakage current shall be measured after 1~2 minutes 
application of the DC rated working voltage through the 
1000 Ω resistor at 20℃.
Dissipation factor﹑leakage 
current, see specification of 
this series.
S1  R
S2  CX
S1 : Swich 
S2 : Swich for protect of
 R : 1000 ± 100Ω  A : 
DC current meter
 V : DC voltage meter
 current meter
CX : Testing capacitor
2. 5
Temperature
characteristics STEP
STORAGE TIME 
1
30 minutes
2
2 hours
3
15 minutes
4
2 hours 
Step 1.   Measure the capacitance and 
impedance. 
( │Z∣, 20℃ , 120Hz ± 10% )
Step 2.  Measure the impedance at thermal balance 
after 2 hours 
( │Z∣, -40℃,  120Hz ± 10% )
Step 4.  Measure the capacitance and leakage current at 
 Step 2.
Impedance ratio  (Zr / Z 
r0
 ) 
less than specified value.
 Step 4
 Capacitance change :
 within ± 
20% of the initial 
measured value.
thermal balance after 2 hours.
Leakage current :
Less than 10 times of initial 
specified value.
20 
±
2 ℃
-40 ± 3 ℃
20 
±
2 ℃
105 ± 2℃
TEST METHOD
SPECIFICATION 
TEMPERATURE 
V 
A 
+
-
Distrelec Schweiz AG, Grabenstrasse 6, 8606 Nänikon, Switzerland, T +41 44 944 99 11, info@distrelec.com, distrelec.com