Datasheet

No. Test item
Performance
Test method (refer to IEC60384-14 )
14
Charge and Discharge
no more than 1A,(whichever the
r
esistance value is the greater) DV/
DT(V/us): 100v/us max
15
Passive fla
mmability
The flaming time of each sampling
capacitor shall not go beyond 30sec after it
is taken apart from the flame. Drop of each
capacitor caused by the flame shall not fire
the tissue below.
Ref 4.17 clause
Needle flame test
The category of flammability :C
Expose time:1time
Capacitor volume Exposing time
250<V(mm
3
)≤500 s=20
500<V(mm
3
)≤1750 s=30
V(mm
3
)>1750 s=60
16
Active flammability
The cheesecloth around the capacitor shall
not burn with a flame.
The specimens shall be invididually
wrapped at least 1 layer, but not more
than 2 layers, complete of
cheesecloth ,the cheesecloth should be
untreated pure cotton. Each sample
shall be subjected to 20
discharged ,the interval between
successtive discharges shall be 5s
Ui=2.5KV±
7
0
%
Metallized Polypropylene Film
Interference Suppression Capacitors
2. Technical Specification
Distrelec Schweiz AG, Grabenstrasse 6, 8606 Nänikon, Switzerland, T +41 44 944 99 11, info@distrelec.com, distrelec.com