Datasheet
Ceramic Disk Capacitors
No  Item  Class I  Class II  Class III  Measuring Condition 
13 
Life 
C
 5﹪or  0.5pF
Whichever is greater
Y5P: 10﹪
Z5U: 20﹪ 
Z5V: 30﹪ 
 Y5P :  ±  15 % 
Applied voltage: 
Rated voltage  ×2(Class I, II) 
Rated voltage  ×1.25(Class III) 
Temperature:85 2℃ 
Duration:1000 
0
48
hrs. 
The chargedischarge current is less than 
10mA. 
The measurements after testing must be 
taken after leaving the sample for 12 to 
24 hours under normal temperature and 
humidity conditions. 
 Perform a heat treatment at 85 2℃
for 1 hour. Remove and let sit for 12 to 24 
hours at normal temperature and 
humidity conditions. Perform the initial 
measurement.
Q╱D.F. 
C≧30pF:Q≧350 
10pF>C<30pF: 
Q≧275 +
2
5
× C 
C≦10pF:Q≧200 + 10 × C 
(C is nominal capacitance) 
Y5P & Z5U: 
tanδ ≦0.05 
Z5V: 
tanδ ≦0.075 
Y5P: tanδ 
≦0.075 
I.R.
More than 1GΩ
More than 1GΩ or 20M Ω ‧
F,whichever is less. 
More than 500MΩ or 10M Ω 
‧F,whichever is less. 
Withstanding 
voltage 
No defects 
Exterior  No abnormalities 
* Note on standard condition:“standard condition”referred to herein is defined as follows:
5 to 35℃ of temperature, 45 to 85﹪relative humidity, and 860 to 1060 mbar of air pressure.
When there are questions concerning measurement results:
In order to provide correlation data, the test shall be conducted under condition of 23℃ 2℃ of temperature, 60 to 70﹪relative humidity, and 860 to 1060 
mbar of air pressure, unless otherwise specified, all the tests are conducted under the“standard condition”.
6.0  Storage 
1. The storage conditions should be:
Temperature = Lower than 40℃ 
Humidity = Lower than 70% R.H. 
2. After opening the package, please store in desiccators.
5.0 Specification
Distrelec Schweiz AG, Grabenstrasse 6, 8606 Nänikon, Switzerland, T +41 44 944 99 11, info@distrelec.com, distrelec.com