Datasheet
RGB LED, 5 mm
Electrical Optical Characteristics at Ta 25℃
Notes:
a. Luminous intensity is measured with a light sensor and filter combination that approximates the CIE eye-response curve.
b. 2θ
1/2
is the o-axis angle where the luminous intensity is 1⁄2 the peak intensity.
c. The dominant wavelength (λd) is derived from the CIE chromaticity diagram and represents the single wavelength which defines
the color of the device.
Parameters Symbol
Emitting
Color
Min. Typ. Max. Unit Test Condition
Luminous Intensity
(a)
Iv
Red 1600 3200 ---
mcd IF=20mAPure Green 2000 4000 ---
Blue 1000 2000 ---
Viewing Angle
(b)
2θ
1/2
Red --- 25 ---
deg. IF=20mAPure Green --- 25 ---
Blue --- 25 ---
Peak Emission Wavelength λp
Red --- 632 ---
nm IF=20mAPure Green --- 520 ---
Blue --- 468 ---
Dominant Wavelength
(c)
λd
Red --- 624 ---
nm IF=20mAPure Green 525
Blue --- 470 ---
Spectral Line Half-Width △λ
Red --- 20 ---
nm IF=20mAPure Green --- 20 ---
Blue --- 25 ---
Forward Voltage VF
Red 1.6 2.0 2.4
V IF=20mAPure Green 2.6 3.2 3.6
Blue 2.6 3.2 3.6
Reverse Current IR
Red --- --- 10
µA VR=5V
Pure Green --- --- 10
Blue --- --- 10
Distrelec Schweiz AG, Grabenstrasse 6, 8606 Nänikon, Switzerland, T +41 44 944 99 11, info@distrelec.com, distrelec.com