Fig. 3.18. TEC power consumption vs operating
temperature
Power, W
0.5
1.0
1.5
2.0
0
–15–20 –10
–5
0
5
10
Temperature, °C
Fig. 3.19. Typical preamplifier output vs operating
temperature
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
–15 –10 –5 0 5 10
Temperature, °C
Output, V
U /U Ratio
mr
U
m
U
r
U/U
mr
0.8
0.6
0.4
0.2
0
3-14