User Manual
42
User's Guide Digiface AVB © RME
13.7.3 OSC Page
The OSC page has four independent settings for up to four MIDI remote controls via Open
Sound Control (OSC). This is a network based remote protocol that can be used for example by
Apple’s iPad with the app TouchOSC or Lemur to wirelessly remote control TotalMix FX running
on a Mac or Windows computer.
Index
Select one of four settings pages and thus remote controls. Settings are remembered automati-
cally. To activate or deactivate any of the four remote controls check or uncheck ‘In Use’.
TotalMix FX OSC Service
¾ IP. Shows the network address of the
computer running TotalMix FX (local
host). This address must be entered on
the remote side.
¾ Host Name. Local computer name.
¾ Port incoming. Must match the remote
entry ‘Port outgoing’. Typical values are
7001 or 8000.
¾ Port outgoing. Must match the remote
entry ‘Port incoming’. Typical values
are 9001 or 9000.
Remote Control
¾ IP or Host name. Enter the IP or host
name of the remote control. Please
note that the IP number usually works
better than the host name.
Options
¾ Send Peak Level. Activates the
transmission of the peak level meter
data. Peak Hold activates the peak
hold function as set up for the TotalMix
level meters in the preferences.
¾ Lock Remote to submix. When
activated the current remote control
can only modify the submix selected
from the drop-down list. This prevents
havoc in multi-remote monitoring
environments.
¾ Number of faders per bank. Available choices are 8 (default), 12, 16, 24, 32 and 48. Note
that when working in underperforming networks, especially wireless, a higher number of
faders might not work as smooth as expected.
13.7.4 Aux Devices
This page integrates RME's OctaMic XTC into the local TotalMix FX. This feature is not
available over network, and therefore not available with the Digiface AVB.