User Manual
User’s Guide OctaMic XTC © RME
59
24. MIDI Implementation OctaMic XTC 
24.1 Basic SysEx Format 
Value
 Name 
F0h SysEx header 
00h 20h 0Dh  MIDITEMP manufacturer ID 
69h  Model ID (OctaMic XTC) 
00h..7Eh, 7Fh  MIDI device ID 
mm Command ID 
nn  Data (parameter index, parameter LSB, parameter MSB, set-flags, ...) 
F7h EOX 
24.2 Message Types - Commands 
Value Name 
10h Request value 
11h  Request level meter data 
012h  Request changed parameters 
020h  Set parameter (multiple parameters allowed) 
30h  Send parameters (multiple parameters allowed) 
Request Value 
Format: F0 00 20 0D 69 (dev ID) 10 F7 
This string triggers a complete dump of all parameter data bytes. 
Value Response 
After being triggered by receiving a request parameter command, device sends a string of all 
parameter data bytes. Message type is set to 30h. 
Set Parameter 
Sets any number of parameters. 
mm / nn can be repeated freely. 
Request Level Meter Data 
Format: F0 00 20 0D 69 (dev ID) 11 F7 
This string triggers a dump of the level meter data. 
0xf0, 0x00, 0x20, 0x0d, 0x69 
MIDI device ID, command ID, parameter index, parameter LSB, parameter MSB, set-flags, ..., 
0xf7 
(… = multiple parameters per message allowed, each consisting of index, LSB, MSB, set-flags) 
Set-flags: set to value from list to set the according parameter in the device, otherwise parame-
ter will be ignored. Set-flags are only assigned for commands containing multiple parameters. 
Messages sent by the device (command ID 0x30) do not contain set-flags. 
Example for MIDI device ID 0 
f0 00 20 0 69 00 20 01 1c 08 7f 0a 30 10 0d f7 
Set Gain Mic 2 to 37dB; Pad on; Phase-Invert, Mute, AutoSet, 48V off; all parameters to be set. 