User Manual
20 
User’s Guide M-32 AD © RME 
Via MIDI remote control, all front panel controls 
of the M-32 AD can be locked (Lock Keys). 
An exception is the key LOCK KEYS. 
Therefore a locking of all the controls can be 
revoked directly at the unit at any time. 
Since firmware 2.1 the fan of the M-32 AD can 
be set. Additonally the internal temperature of 
the M-16 and M-32 is displayed. 
The software MIDI Remote also controls 
RME’s ADI-648, ADI-6432, ADI-642, Micstasy, 
ADI-8 QS and the MADI Bridge. 
The following functions can only be set via 
MIDI Remote: 
- Setting of Word Clock Out as Follow Clock or 
Always Single Speed 
- Changing the Device ID 
- Fan control 
Fan Modes 
Cool 
In Cool mode the fan runs all time with speed 
3. From 48°C up it changes to speed 5 (max.), 
below 45°C it switches back to speed 3. 
Normal 
Factory default 
Silent 
In Silent mode the fan starts not before 48°C 
and with highest speed. Below 45°C the fan is 
switched off again. 