User Manual
User’s Guide M-32 AD © RME
19
The block diagram shows the signal 
flow in a HDSP MADI-based remote 
control system. MIDI commands from 
a software on PC or Mac travel from 
the MADI Out of the HDSP MADI to 
the MADI In as well as to the MIDI 
Out and MADI Out of the M-32 AD. 
Additional to the remote commands 
further MIDI data can be transmitted, 
available then at the DIN MIDI output 
jack of the M-32 AD. However, MIDI 
signals at the DIN input jack can not 
travel back to the computer. With 
input setting MIDI the other direction 
is active. MIDI data travel from the 
MADI out to the computer, but not 
back from the computer via MADI to 
the M-32 AD. 
9.3 Remote Control Software 
A free remote software for Windows and Mac OS X can be downloaded from the RME website. 
It can use any existing MIDI port within the system to perform remote control and status re-
quests of any number of M-series converters via a simple mouse click. Most appealing is the 
combination with a HDSP(e) MADI, offering a direct control of the M-32 AD via MADI. The re-
mote control software then uses a virtual MIDI port of the card, which directly sends and re-
ceives MIDI data via MADI. 
Software download: http://www.rme-audio.de/en_downloads.php 
Brief description of the Windows/Mac OS X Software MIDI Remote 
The unique multi-window concept of the software MIDI Remote allows for a simultaneous 
usage and configuration not only of multiple M-32 ADs, but also of all other supported devices, 
even in mixed setups. The function M-32 AD has been extended compared to the unit. Settings 
not available at the unit’s front can be controlled, the gain reduction is shown on separate 
meters etc. Names can be assigned to all channels and all devices. 
The program includes an extensive English online help (F1). After the start first choose the 
function M-32 AD in the menu Functions (also available via F4). 
Then select a MIDI input and output via Options - MIDI I/O Setup. 
Using the command Options – Start/Stop MIDI I/O the communication with the M-32 AD is 
started. The top line of the program window shows the current state, like selected ID, Online / 
No Response / Offline etc. 
Save Workspace as allows to store complete setups including all windows in a file, and to re-
load them at any time. 
Send Single Set of Data realizes an offline configuration of the M-32 AD, and uses a single 
one-time transmission of all settings. 