19.6 Preferences
The dialog Preferences can be opened via the Options menu or directly via F2.
Level Meters
¾ Full scale samples for OVR. Number
of consecutive samples to trigger an
over detection (1 to 10).
¾ Peak Hold Time. Hold time of the peak
value. Adjustable from 0.1 up to 9.9 s.
¾ RMS +3 dB. Shifts the RMS value by
+3 dB, so that full scale level is identical
for Peak and RMS at 0 dBFS.
Mixer Views
¾ FX Send follows highest Submix.
¾ FX Send follows Main Out. Not
available for the Digiface USB - no FX.
¾ Center Balance/Pan when changing
Mono/Stereo. When switching a stereo
channel into two mono channels the
pan-pots are set fully left and right. This
option will set them to center instead.
¾ Disable double click fader action.
Prevents unintentional gain settings, for
example when using sensitive touch-
pads.
¾ Store channel open/close in Layout
Preset. Also loads the state of the
channel panels (Settings).
Dynamic Meters
Not available for the Digiface USB.
Snapshots
¾ Do not load - Main Volume,
Main/Phones Volumes, Control Room
Settings. The selected values stored in
the Snapshot are not loaded, so the
current setting is not changed.
Device Handling
¾ Always init DSP devices with
TotalMix FX settings. For the Digiface
USB: always on, as the unit does not
store any. When connecting to a
computer TotalMix FX will immediately
load its settings into the Digiface USB.
¾ Count MADI Channels per port. Not available for the Digiface USB.
¾ Disable ASIO Direct Monitoring. Disables ASIO Direct Monitoring (ADM) for the Digiface
USB within TotalMix FX.