User's Manual

28
User’s Guide ADI-2 DAC v2.2 © RME
14.1.4 Display
The subpage Display has the following entries:
Display Mode
Available settings are: Default, Dark. The dark scheme inverts the white background and black
numbers/text to black background and light-grey numbers/text in all menus.
Meter Color
Green, Cyan. Amber. Default: Green. Sets the meter screen colour in PCM and DSD mode.
Hor. Meter
The horizontal stereo level meter below the Analyzer can show the peak level before all DSP
processing (Pre, equals the current input level from USB playback and SPDIF In), after all
processing including volume control (Post), or both at the same time (Dual). The outer thin line
is the Pre level. In Dual mode the peak values to the right refer to Post level.
AutoDark Mode
OFF, ON. Default: OFF. Automatically turns off all LEDs and the display after 10 seconds of
user inactivity. A key press, turning an encoder, warning messages and the remote control will
temporarily activate LEDs and display again. Using the remote the time for entering dark mode
is 3 seconds.
Show Vol. Screen
ON, OFF. Default: ON. When turning the VOLUME knob the Volume screen is shown.
LCD Brightness
Adjustable from 20% to 100%. Default is 80%.
LCD Tint Control
Adjustable from -8 (yellow) to 8 (blue). Enables compensation of the display's colour deviation
as well as suiting the user's taste.
14.2 Load/Store all Settings
This option allows to save the whole state of the unit as Setup in up to 9 different memory slots.
The EQ Presets are not included, they are stored separately and are available for any setup.
The current state of the EQ is also stored. During load of a Setup the EQ is written to the mem-
ory slot Manual.
The page Setups, Load/Store all Settings, has the following entries:
Setup Select
Choices are Load 1-9, Factory (Reset All) and Store 1-9.
Name
Allows to edit the name of the Setup during the store
process. To edit an existing name load the respective Setup
and store it on the same memory slot with edited name. See
EQ - Name for details about the Edit operation.
Start
Press 1s. Pressing and holding encoder 2 for at least one second triggers the action selected
(Load or Store).
Returning to Factory State
Is described in chapter 7, page 11.