User's Manual
28 
User’s Guide ADI-2 DAC v2.2 © RME 
14.1.4 Display 
The subpage Display has the following entries: 
Display Mode 
Available settings are: Default, Dark. The dark scheme inverts the white background and black 
numbers/text to black background and light-grey numbers/text in all menus. 
Meter Color 
Green, Cyan. Amber. Default: Green. Sets the meter screen colour in PCM and DSD mode. 
Hor. Meter 
The horizontal stereo level meter below the Analyzer can show the peak level before all DSP 
processing (Pre, equals the current input level from USB playback and SPDIF In), after all 
processing including volume control (Post), or both at the same time (Dual). The outer thin line 
is the Pre level. In Dual mode the peak values to the right refer to Post level. 
AutoDark Mode 
OFF, ON. Default: OFF. Automatically turns off all LEDs and the display after 10 seconds of 
user inactivity. A key press, turning an encoder, warning messages and the remote control will 
temporarily activate LEDs and display again. Using the remote the time for entering dark mode 
is 3 seconds. 
Show Vol. Screen 
ON, OFF. Default: ON. When turning the VOLUME knob the Volume screen is shown. 
LCD Brightness 
Adjustable from 20% to 100%. Default is 80%. 
LCD Tint Control 
Adjustable from -8 (yellow) to 8 (blue). Enables compensation of the display's colour deviation 
as well as suiting the user's taste. 
14.2 Load/Store all Settings 
This option allows to save the whole state of the unit as Setup in up to 9 different memory slots. 
The EQ Presets are not included, they are stored separately and are available for any setup. 
The current state of the EQ is also stored. During load of a Setup the EQ is written to the mem-
ory slot Manual. 
The page Setups, Load/Store all Settings, has the following entries: 
Setup Select 
Choices are Load 1-9, Factory (Reset All) and Store 1-9. 
Name 
Allows to edit the name of the Setup during the store 
process. To edit an existing name load the respective Setup 
and store it on the same memory slot with edited name. See 
EQ - Name for details about the Edit operation. 
Start 
Press 1s. Pressing and holding encoder 2 for at least one second triggers the action selected 
(Load or Store). 
Returning to Factory State 
Is described in chapter 7, page 11. 