User Manual

18
User's Guide ADI-4 DD © RME
10.6 4-channel AES Single Wire to AES Double Wire Converter (96 kHz)
SOURCE: AES
Remark: When DS is not active and the input signal is in Single Wire Double Speed format, the
data will be converted to Double Wire Single Speed. Because only 8 physical output channels
are available, there will only be 4 audio channels effectively. The inputs 5 - 8 cannot be trans-
mitted via AES. For this application, the ADAT ports have to be bridged with a loop-back cable
(OUT 1 to IN 1, OUT 2 to IN 2). ADAT must not be chosen as clock source (SYNC).
10.7 8-channel ADAT to AES Converter (96 kHz)
SOURCE: ADAT
Remark: If the input data is encoded in Sample Split (S/MUX) format, the DS function has to be
activated manually in order to have the AES outputs transmit 8 channels in Double Speed Sin-
gle Wire.
10.8 8-channel ADAT to 2 x ADAT Splitter (48 kHz)
SOURCE: ADAT
Remark: For sample rates below 56 kHz the outputs OUT 1 and OUT 2 will carry the same
data. Thus two ADAT outputs can be used (splitter). This application requires a loop-back ca-
bling of all 4 AES inputs and outputs (AES1 Out to AES 1 In etc).