17.3 AD/DA Converter
AD/DA: Converter Mode, analog in to all digital outs, digital in to all analog outs.
This mode can be activated manually by selecting Basic Mode – AD/DA. The device enters
AD/DA mode automatically when Basic Mode is set to Auto and a digital input signal is de-
tected.
The detected digital input signal will also become the signal source. In case more than one digi-
tal signal is found the user has to manually select the source to be monitored (I/O – Output
Channel - Settings – Source). The SRC is active by default, assigned to SPDIF, but switched off
automatically if a DoP signal (DSD) is detected. Clock mode is slave to AES in, but will adapt to
the detected source (Auto).
Note
: To simplify the diagram and to maintain overview USB record is not shown. In all modes
all input signals are sent over USB to the host. In multi-channel mode three separate stereo
pairs, in stereo mode only the stereo analog input.
USB Playback channels 3/4 can only be monitored in multi-channel mode. In stereo mode se-
lecting USB 3/4 plays channels 1/2.
The option Digital Out Source - Main Out (SETUP – Options – Device Mode / DSD) sends the
processed signal Main Out 1/2 to the digital outputs AES, SPDIF and ADAT, for example to
connect active monitors having digital inputs.