Connecting a TEB to the second ADAT In of a
HDSP 9652. Remove the jumper ST5, plug
DIGOUT of the TEB on both right and middle
pin of ST5.
6. Operation and Usage
Switch on the computer and boot the OS. The green LED on the TEB is lit when the power
supply is present. The red LED will be off as soon as the TEB receives a valid ADAT input sig-
nal via the DIG IN connector.
DIGI96 series
Start the Settings dialog of the DIGI96/8 series, select the internal input (Input 'Internal'), set
Clock Mode to 'Master'.
Connect the external device, which must be in clock mode slave, to the TDIF jack
Connect the word clock output of the TEB with the word clock input of the TDIF device
Verify that the clock select switch of the TEB is pressed
The Input Status must now show 'ADAT, 44.1 kHz, Internal' (or 48 kHz). In case 'No Lock' is
shown either the clock mode is not set up correctly, or the TEB is not connected correctly.
Hammerfall series and HDSP 9632/52
Start the Settings dialog of the Hammerfall, select the internal input (AEB 'ADAT1 Internal'),
set Clock Mode to 'Master'.
Connect the external device, which must be in clock mode slave, to the TDIF jack
Connect the word clock output of the TEB with the word clock input of the TDIF device
Verify that the clock select switch of the TEB is pressed
The Input Status in the field SyncCheck must now show 'ADAT1 In SYNC'. In case 'Lock' or 'No
Lock' is shown either the clock mode is not set up correctly, or the TEB is not connected cor-
rectly.
Clock Select Switch
The Clock Select switch of the TEB defines which reference clock is used by the TEB.
Pushed: ADAT (PCI card)
not pushed: TDIF (external device)
We recommend to set the switch according to the device being the current clock master. When
the external TDIF device is master: switch not pushed. With PCI card being master: switch
pushed.