7.2 Detailed Input Status 
While in the status display, rotating or pushing the [IN] encoder immediately activates 
the 'Inspect Input' screen. This page shows the detailed status of an input port selected 
by turning the [IN] encoder. Information about all other ports including routing is hidden 
in order to allow a dedicated focus on the selected input port. Pressing either encoder 
exits the detailed view and returns to the main status display. 
In this detailed view of the input status, the following information is displayed for each 
physical MADI input port:  
●  Lock | Invalid | No signal 
Lock: a MADI signal is detected and has been present for a minimum of 
1 second. 
Invalid  signal:  a  signal  is  detected  but  it  violates  MADI  (AES10) 
definitions 
    No signal: no signal is detected for more than one second. 
●  Rate: 32 kHz – 192 kHz 
Shows the sampling rate of the MADI input: 
●  32kHz, 44.1kHz, 48kHz in 48k frame mode 
●  88.2kHz, 96kHz in 96k frame mode 
●  176.4kHz, 192kHz in a non-standard 192k frame (experimental) 