User guide

42
User's Guide MADIface XT © RME
The page MADI Settings has the following entries:
MADI 1/2/3 Format
Can be set to 56 or 64 channels.
MADI 1/2/3 Frame
Can be set to 48k or 96k.
Redundancy M
Redundancy Mode.
Mirror Output
On or Off.
.
These options are explained in detail in chapter 7.1 / 14.1.
The page Control Room has the following entries:
Main Out
Defines the mixer’s Main output.
Dim
Defines the amount of Dim on the Main output.
Dim Active
Activates Dim on the Main output.
Recall Volume
Stores a volume value which can be is called by the Recall button on the external remote
(ARC).
These options are explained in detail in chapter 25.4.
19.5.2 Setups Menu
The page Setups, Load/Store all Settings, has the following entries:
Setup Select
Choices are memory slots 1 to 6 and Factory (factory default).
Operation
Choices are Load and Store.
Start
Press 1s. Pressing and holding encoder 2 for at least one second
triggers the action selected in Operation.
These options are explained in detail in chapter 23.1.