User`s guide
User's Guide HDSPe MADI FX © RME
15
TMS
TMS activates the transmission of
Channel Status data and Track
Marker information from the AES and
MADI input signal.
Redundancy Mode
With redundancy mode active the
number of input channels is reduced
to 66 (AES plus 1x MADI). The two
other MADI ports serve as fail safe
inputs and are used as soon as the
signal on the 'Current MADI Input'
fails. This setting is also a perfect
choice if the card is used as single
MADI I/O, saving resources and
providing simpler channel selection
dialogs.
Mirror MADI1 Output to MADI2/3
This option provides a quick and
simple solution to mirror the first
MADI output to outputs 2 and 3. The
outputs are reduced to 2+2+64
channels (AES, Phones and one
MADI port). All the data routed and
mixed to MADI port 1 is sent to MADI
port 2/3 as well.
Input Status
Displays the state of the current input
signal:
• Clock state (No Lock, Lock, Sync)
• Sample rate (coarse)
• MADI Frame format (48K or 96K)
• Channel format (64 or 56
channels)
Sync Check
RME’s exclusive SyncCheck technology provides an easy to use check and display of the cur-
rent clock status. The clock state column indicates whether no signal (No Lock), a valid signal
(Lock) or a valid and synchronous signal (Sync) is present at each of the digital clock source