User`s guide
32
User's Guide Fireface 400 © RME
Word Clock Out
The word clock output signal
usually equals the current sample
rate. Selecting Single Speed
causes the output signal to always
stay within the range of 32 kHz to
48 kHz. So at 96 kHz and 192 kHz
sample rate, the output word clock
is 48 kHz.
Sample Rate
Used to set the current sample
rate. This is the same setting as in
the Audio MIDI Setup, just added
here for your convenience.
System Clock
Shows the current clock state of
the Fireface 400. The unit is either
Master (using its own clock) or
Slave (AutoSync Ref).
Limit Bandwidth
Allows to reduce the amount of
bandwidth used on the FireWire
bus. See chapter 15.3. Available
options:
All channels (default)
Analog + SPDIF
Analog
Read (Flash Memory)
A click on this button causes all settings to change to the ones stored in the flash memory of the
Fireface.
Store (in Flash Memory)
A click on this button transmits all current settings into the flash memory of the Fireface. Those
settings then become active directly after power-on, and also in stand-alone operation.