User`s guide

User's Guide Fireface 400 © RME
31
Analog Inputs
1 Mic, 2 Mic
Gain setting for the microphone preamps of input 1 and 2. The current gain is displayed in dB to
the left of the fader. Phantom power (48V) can be selected for each microphone input sepa-
rately. The option Link simplifies the setup in case both channels shall have the same set-
ting/values.
In the lower range the fader jumps from 10 dB to 0 dB. This useful additional setting allows to
operate even line signals with the microphone input (up to +10 dBu).
3 Line, 4 Line
Gain setting for the line/instrument inputs 3 and 4. The current gain is displayed in dB to the left
of the fader. Activate the option Inst to use inputs 3 and 4 with instruments. The input imped-
ance is raised to 470 kOhm, the input sensitivity increases by 10 dB. Pad decrease the input
sensitivity by 12 dB.
5-8 Line
Defines the reference level for the rear analog inputs 5-8.
Analog Outputs
1-6 Line
Defines the reference level for the rear analog outputs 1-6.
7-8 Phones
Defines the reference level for the rear analog outputs 7/8.
Digital Settings
SPDIF In
Defines the input for the SPDIF signal. 'Coaxial' relates to the RCA socket, 'Optical' to the opti-
cal TOSLINK input. The current sample rate of the SPDIF input signal is also displayed.
SPDIF Out
The SPDIF output signal is constantly available at the phono plug. After selecting 'Optical' it is
also routed to the optical TOSLINK output. For further details about the settings ‘Professional’,
‘Emphasis’ and ‘Non-Audio’, please refer to chapter 23.2.
Clock Mode
The unit can be configured to use its internal clock source (Master), or the clock source pre-
defined via Pref. Sync Ref (AutoSync).
Preferred Sync Ref / Input Status
Used to pre-select the desired clock source. If the selected source isn't available, the system
will change to the next available one. The current clock source and sample rate is displayed in
the AutoSync Ref display. The automatic clock selection checks and changes between the
clock sources Word, ADAT and SPDIF.
AutoSync Ref
Displays the current clock source and sample rate of the clock source.