User`s guide
User's Guide Fireface 400 © RME
23
9. Operation under ASIO
9.1 General
Start the ASIO software and select ASIO Fireface as the audio I/O device.
Fireface 400 supports ASIO Direct Monitoring (ADM).
The Fireface 400 supports both MME MIDI and DirectMusic MIDI.
9.2 Channel Count under ASIO
At a sample rate of 88.2 or 96 kHz, the ADAT optical input and outputs operate in S/MUX mode,
so the number of available channels per port is reduced from 8 to 4.
Note
: when changing the sample rate range between Single, Double and Quad Speed the num-
ber of channels presented from the ASIO driver will change too. This may require a reset of the
I/O list in the audio software.
Single Speed Double Speed Quad Speed
Fireface 400 Analog 1 to 8 Fireface 400 Analog 1 to 8 Fireface 400 Analog 1 to 8
Fireface 400 SPDIF L / R Fireface 400 SPDIF L / R Fireface 400 SPDIF L / R
Fireface 400 ADAT 1 to 2 Fireface 400 ADAT 1 to 2 Fireface 400 ADAT 1 to 2
Fireface 400 ADAT 3 to 4 Fireface 400 ADAT 3 to 4 Fireface 400 ADAT 3 to 4
Fireface 400 ADAT 5 to 6 Fireface 400 ADAT 5 to 6 Fireface 400 ADAT 5 to 6
Fireface 400 ADAT 7 to 8 Fireface 400 ADAT 7 to 8 Fireface 400 ADAT 7 to 8