User`s guide

14
User's Guide Fireface 400 © RME
7.2 Settings Dialog – Analog
Level
Line In
Defines the reference level of the
rear analog inputs 5-8. The
available settings are -10 dBV, +4
dBu and LoGain.
Line Out
Defines the reference level of the
rear analog outputs 1-6. The
available settings are -10 dBV, +4
dBu and HiGain.
Phones
Defines the reference level of the
analog outputs 7/8. The available
settings are -10 dBV, +4 dBu and
HiGain.
Microphone Inputs
Channel 1/2 of the Fireface 400
have digitally controlled
microphone preamps of the
highest quality. The digital control
offers a gain setting in steps of 1
dB within a range of 10 dB to 65
dB. The configuration is done
either directly at the unit via the
rotary encoder, or via the Settings
dialog's tab Analog.
The option Link simplifies the setup in case both channels shall have the same setting/values.
The current gain is displayed in dB below the fader.
In the lower range the fader jumps from 10 dB to 0 dB. This useful additional setting allows to
operate even line signals with the microphone input (up to +10 dBu).
Instrument/Line Inputs
The inputs 3 and 4 have digitally controlled preamps. They allow for an additional gain between
0 and 18 dB, in steps of 0.5 dB. The configuration is done either directly at the unit via the rotary
encoder, or via the Settings dialog's tab Analog. The option Link simplifies the setup in case
both channels shall have the same setting/values. The current gain is displayed in dB below the
fader. Further information is found in chapter 21.3.
Activate the option Inst to use inputs 3 and 4 with instruments. The input impedance is raised to
470 kOhm, the input sensitivity increases by 10 dB. Pad decreases the input sensitivity by 12
dB to prevent overload.