7.8 Pull up the panels together, so that the connections are exactly opposite each other.
Using pair of the spanners tight the compression tting.
7.9 On both the ow and return connection attach the brass T-piece with air vent
(supplied). Lubricate the O-rings with silicon or glycol before tightening airvent
connection.
7.10 Connect the brass T-pieces with copper or exible stainless steel pipe.