User's Manual
Document:
TBD
Page:
35 of 42
ENGINEERING
Documentation
Revision:
1.6
Date:
24-May-17
Title:
TND540 Requirement
Proprietary and Confidential
This document contains confidential and property information which belongs to Rand McNally, Inc. This
document may not be copied, reproduced, or transmitted to others in any manner, nor may any use of the
information on this document be made, except for the specific purposes for which it is transmitted to the
recipient without prior written consent of Rand McNally, Inc.
The half-sine pulse shall meet following profile specified in MIL-STD-202G.
4.3.3 Transport Shock
The product shall perform in accordance with this specification after exposure to the Standard Test Method
for Drop Test of Loaded Containers by Free Fall (ASTM D 5276, A2.2.4). The test shall be performed with the
unit packaged for shipment. A total of 2 packages shall be used for this test.
Note: A2.2.4 Twenty-six drop cycle – Drop the test package on each flat face, edge and corner.
4.3.4 Drop Requirement
The product shall perform in accordance with this specification and no visible damage after 1 meter drop on to
a level concrete surface one time each of the three mutually perpendicular planes (three drops total). A total
of 2 units shall be used for this test.
PDF 檔案使用 "pdfFactory Pro" 試用版本建立 www.pdffactory.com