3.2.5 Acceptance Test Criteria
The following criteria in accordance with IEC 1000-4-x and EN 50082-1 shall be used for determination of
product acceptance to the requirements defined herein.
A Normal performance within specified limits
B Temporary degradation in performance or loss of function which is self-recoverable
C Temporary degradation in performance or loss of function that requires operator intervention or
system reset.
D Degradation or loss of function that is not recoverable due to damage of equipment (components) or
software, or loss of data. No unsafe condition permitted.
3.2.6 Test Reports
Subsequent to the completion of the test, a detailed test report summarizing the results obtained shall be
generated. The test report shall include executive summary including a list or reference to test requirements,
list of deviations or exceptions to these requirements, sample description and identification, test setup, and
any limitations of the test.
ODM shall provide HW test report per RM requirement for all development phase;
P1 5 units
P2 5 units
ODM shall provide OS regression test report per RM requirement for all official OS release;
ODM shall provide all environmental test report conducted on the final HW version;
4 Environmental Conditions
4.1 Thermal Requirements
The thermal requirements for TND540 specified herein are adapted from the Department of Defense Test
Method Standard for Environmental Engineering Considerations and Laboratory Tests (MIL-STD-810F).
4.1.1 Operating Temperature
The product shall operate in accordance with this specification before, during and after exposure to
temperatures ranging from 10
o
C to +60
o
C. A total of 5 units shall be used for this test.
4.1.2 Survival Temperature
Not applicable