RLH Industries, Inc.
RLH Industries, Inc. Copyright © 2013 RLH Industries, Inc. All rights reserved. No part of this document may be copied or distributed without permission. The RLH logo may not be used for commercial purposes without the prior written consent of RLH and may constitute trademark infringement. Other company and product names mentioned herein are trademarks of their respective companies.
Contents 1. Important Information Intended Audience 5 Conventions 5 General Safety Practices 5 2. Introduction Product Description 6 Standard Features 6 Application Diagrams 7 Front Panel 8 Front Panel LEDs 8 Module Status LEDs 9 LAN/MGMT Port LEDs 9 Optical Module LEDs 9 Rear Panel 10 4 Channel E1 Module 10 4 Channel T1 Module 10 4 Channel RS-232 Module 11 4 Channel V.
Prepare for Installation 18 Check for shipping damage 18 Verify system contents 18 Verify matching optical module and fiber modes 18 Site Requirements 18 Site selection 18 Typical application environments 19 Required power sources 19 Test Equipment 19 For T1 service 19 For analog phone service (POTS) 19 For RS-232 service 19 4.
1. Important Information Intended Audience This manual is intended for use by knowledgeable telco/network installation, operation and repair personnel. Every effort has been made to ensure the accuracy of the information in this manual is accurate. However, due to constant product improvement, specifications and information contained in this document are subject to change without notice. Please refer to the iMux User Guide for additional information.
2. Introduction Product Description The iMux is a powerful fiber optic modular multiplexer capable of providing up to 16 channels of T1, RS232, 2/4 wire data and analog phone FXO/FXS services, plus four built-in 10/100M Ethernet ports, over a single fiber. These services are supplied by the modules, up to four, that each offer four lines of communication and may be installed in any combination. Spares or add-on modules may be ordered separately and are field installable.
Application Diagrams POTS (FXO) T1 2/4 Wire Data POTS (FXS) T1 2/4 Wire Data Fiber Optic Cable Up to 74 mi.
Front Panel MAJ WK LSR ON TX RX LOS WK LSR ON TX RX LOS E1/V35 1 2 3 4 PWR MIN LCK LB K ACO EXT CLK SL-2100 1 2 3 RDI 4 LOS/LOF/AIS LAN1 LAN2 LAN3 LAN4 MGMT CRAFT RST Front Panel LEDs LED Color Name MAJ RED Major Alarm ON condition Major alarm event is present and OFF condition Normal operation being signaled through rear panel alarm connector. MIN YEL Minor Alarm Minor alarm event is present and Normal operation being signaled through rear panel alarm connector.
Module Status LEDs E1/V35 1 2 3 4 IMux slot number N1 LAN2 LAN3 LAN4 MGMT PWR LCK ACO PORTS MAJ MIN LBK RDI ACO 1 2 3 4 Port number on each module RST CRAFT LOS/LOF/AIS LED Name Color PORT Installed port slot RED No module is installed at this port number GRN A module is installed at this port number Module port status for RED No connection is detected to that port any installed module GRN Active connection is attached to that module port E1/V35 Condition Note: Although the por
Rear Panel Any of the modules may be plugged into any position, called a Tributary Slot. These are referred to as TB1~TB4. 3-2 Rear Panel Refer to the Specifications section for additional information.
4 Channel RS-232 Module 4xRS-232 module, HD68 to 4 DB-9 connectors to RS-232 interface. Breakout adapter cable is included. (f) RS232 tributary card 1 5 DB-9 Female DCE RS232 6 9 Pin Description I/O 1 2 3 4 5 6 7 8 9 DCD TXD RXD DTR SG DSR RTS CTS RI Output Output Input Output GND Input Output Input Output Any kind of the above cards is allowed to plugged into tributary slot 1~4. (c) 4V35 tributary card (TB1~TB4) 4 Channel V.35 Module 4*V35 card, HD68 to 4*M34 Connectors to V.35 interface.
4 Channel Analog Phone (POTS) Modules Analog phone uses RJ-11 connectors and are supplied as FXS/Sub side and FXO/CO side modules. The FXO/CO module is connected to a central office or PBX, and the FXS/Sub module is connected to the customer telephone. Each line number FXO raises the same line number FXS, and provides 64k voice bandwidth. Use an FXS module on each end for ringdown operation where connection to phones on both ends of the system is desired.
4 Channel 2/4 Wire Analog Data/Audio/SCADA Module Four Analog 2/4 Wire Data/Audio/SCADA modules use RJ-11 connectors. Each channel has 300Hz ~ 3.4kHz bandwidth. Analog Channel FXO FXS Input PIN 1 PIN 4 4 PIN RJ-11 Female Output Pin Description 1 Tip 4 Ring 2 Tip 3 Ring 4 Channel 2/4 Wire Analog Data/Audio/SCADA/E&M Module Four Analog 2/4 Wire Data/Audio/SCADA/E&M modules use RJ-45 connectors. Each channel has 300Hz ~ 3.4kHz bandwidth. E&M type is set in software.
Setting E&M Jumpers and Switches Use the J2 jumper and the J4 DIP switches to set the E&M module mode to Master or Slave depending on the placement of the iMux in the network. The diagram on the following pages will help you determine the correct settings for your application. Refer to the diagram below for configuration settings.
Analog E&M 4-Wire Audio Operation PBX Tie-Line Cisco Equipment Slave Master 4 Wire E&M Card 4 Wire E&M Card E&M E&M Fiber Optic Cable (-48V) iMux PBX (-48V) iMux Tie-Line Cisco Equipment On-hook On-hook -48V E detect 7 E Off-hook -48V E 7 M 6 detect Off-hook E Off-hook Off-hook M -48V ptc GND 6 M detect -48V 8 On-hook On-hook T R 4-Wire Audio T1 R1 Trunk Circuit 8 ptc 2 T 3 R 5 T1 4 R1 4-Wire Audio 4-Wire Audio T 2 R 3 T1 5 R1 4 Signalling
Acronyms Commonly used acronyms and abbreviations Acronym/Abbreviation B8ZS Bipolar 8 Zero Substitution FXO/CO Central Office Side Equipment FXS/Sub Subscriber side equipment LED 16 Description Light Emitting Diode RX Receive TX Transmit RED Red LED color YEL Yellow LED color GRN Green LED color RLH Industries, Inc. • 866-DO-FIBER • www.fiberopticlink.
3. Before Installing Observe Special Handling Requirements Be careful when handling electronic components ATTENTION ELECTROSTATIC SENSITIVE DEVICES • This product contains static sensitive components. • Handle the T1/E1 cards and optical modules by their faceplates only. • Follow proper electrostatic discharge procedures. This card utilizes circuitry that can be damaged by static electricity.
Prepare for Installation Check for shipping damage Carefully unpack and inspect the unit and accessories. Contact RLH immediately if any components are damaged or missing. Electronic components, fiber optic cable, and accessories have special handling requirements to prevent damage and enhance system reliability. If the iMux will be relocated in the future, save the cartons and protective packaging material.
Typical application environments Install the fiber optic cable prior to installing the iMux system. Required power sources You will need an acceptable power source. The iMux system accepts 90 ~ 240VAC (47Hz ~ 63Hz) and 12, 24 or 48VDC (9 ~ 75VDC) depending on the model. The F.C.C. requires telecommunication equipment to withstand electrical surge that may result from lighting strikes. This equipment has been tested and found to comply with the F.C.C. requirement.
4. Quick Start Easy Installation Before starting • Review the safety information in section 1. Important Information • Familiarize yourself with the iMux and it’s modules as described in section 2. Introduction • Know how to handle fiber optic cable, have a suitable installation environment with the correct power, and have the necessary test equipment as described in section 3.
Connect ethernet cables • Attach ethernet cables to the RJ-45 ethernet ports labeled LAN1 through LAN4 on the front panel of the iMux. Connect data/phone equipment Attach the breakout adapters and cables depending on your iMux module configuration. Connect T1 cables • Attach the breakout adapter cable to the DB-25 connector on the T1 module. • Connect the RJ-45 T1 connectors to the breakout adapter cables.
5. Specifications General Specifications Alarm Power Supply Environment Other Contact Capacity External Alarm AC DC Power consumption Working Temp. Working Humidity Storage Temp., Humidity EMI 4 relay contacts (DB-9 connector) DB-9 connector 115/240V (90~240V) (47Hz~63Hz) 48V (36~75V) 30W maximum 0˚C ~ +50˚C (32˚F ~ 122˚F) 5% ~ 95% RH non-condensing -20˚C ~ 60˚C (-4˚F ~ 140˚F), 5% ~ 95% RH Comply with CISPR 22 class A (EN55022), FCC part 15 class A MTBF Dimensions subpart B 48,000 hours minimum W 17.
Service Module Specifications T1 Interface Module 10/100M Ethernet Interface RS232 Module (DCE) 2/4W Data/SCADA Module Specifications Channel Capacity Bit Rate Line Code Line Framing Input Jitter Tolerance Output Jitter Tolerance Line impedance Compliance Configuration modes Maximum packet length Frame buffer MAC Table VLAN/QOS function Port Rate Control Connector Ports Channel Capacity Bit Rate Local loopback Remote loopback Channel capacity Connector Bandwidth Impedance Longitudinal Conversion Loss
6. Ordering Information Base Systems Part Number RLH-IMUX-V-2 RLH-IMUX-A-2 Description Power 1 Power 2 48VDC 48VDC 115/220VAC 48VDC iMUX BASE SYSTEM DUAL 48 VDC INPUT PWR iMUX BASE SYSTEM AC/DC & 48VDC INPUT PWR Dimensions (1RU) W17.3in x D11.2in x H1.75in (440mm x 285mm x 44.5mm) W17.3in x D11.2in x H1.75in (440mm x 285mm x 44.5mm) Optics and Service Modules are ordered separately and are pre-installed. System is pre-configured before shipping for quick and easy operation.
Optical Modules Part Number Description Side Distance Fiber Part Number Multimode ST iMux Optical Module - 2 km/1.2 mi 62.5 μm RLH-OM-04-1 iMux Optical Module A 20km/12.4mi. 8~9 μm RLH-OM-10-1 iMux Optical Module B 20km/12.4mi. 8~9 μm RLH-OM-11-1 iMux Optical Module A 60km / 37mi. 8~9 μm RLH-OM-14-1 iMux Optical Module B 60km / 37mi. 8~9 μm RLH-OM-15-1 iMux Optical Module - 20km/12.4mi. 8~9 μm RLH-OM-40-1 iMux Optical Module - 60km / 37mi.
7. Support Technical Support Email: support@fiberopticlink.com 24/7 technical support: Toll Free 1-855-RLH-24X7 Toll Free 1-855-754-2497 Contact Information Corporate Headquarters: RLH Industries, Inc. 936 N. Main Street Orange, CA 92867 USA Phone: (714) 532-1672 Toll Free 1-800-877-1672 Toll Free 1-866-DO-FIBER Fax: (714) 532-1885 Email: info@fiberopticlink.com Web site: www.fiberopticlink.com RLH Industries, Inc. 936 N.