User guide
[F1] Aggr Circuit Identifier
OE 1 Circuit Identifier
OE 2 Circuit Identifier
Enter Circuit Identifier names as desired.
[F3] Working OE (Working Optical Enable)
Set the primary working optical interface.
[F4] ALS (Auto Laser Shutdown)
Please refer to the definition of ITU-T G.664, when the iMux detects LOS and the ALS function is enabled at the
same time, then OE will shutdown the signal of Tx. It will detect the signal automatically every 100 seconds. If the
alarm of LOS isn’t cancelled immediately, then it will wait another 100 seconds again. If the LOS status is
cleared, the system will return to normal state and transmit the laser signal again.
[F5] Standby OE Service (Standby Optical Enable Service)
Enable or disable the Standby Optical Service.
[F6] APS (Auto Protection Switch)
Set the optical auto protection to ON or OFF. When set to OFF, OeLocked/OeLocked Rule/Oe Lock
AutoRel Sec will not be displayed.
[F7] OE Revertive (Optical Enable Revertive)
When set to OFF, OeLocked/OeLocked Rule/Oe Lock AutoRel Sec will not be displayed.
[F8] OE Locked (Optical Enable Locked)
Set the optical enable locked to ON or OFF.
When set to OFF, OeLocked Rule/Oe Lock AutoRel Sec will not be displayed.
When set to ON:
•
Locks the optical system according the parameters set in the OE Locked Rule settings. Set the time window in
minutes, and the number of times. The default setting is 10 minutes, 6 times.
•
The OE Locked AutoRel (Auto Release) may be set will be auto-release after a user defined duration in seconds.
The default setting is 3600 seconds.
Note:"If OE Locked is ON, then it needs to be released on the OE Protection Switching screen.
Note:"When any setting is changed that causes the OeLocked/OeLocked Rule/Oe Lock
AutoRel Sec settings to be no longer displayed, rebooting the system will reload the
default values.