User guide

Troubleshooting Guide
No.
Symptom
Probable Cause
Corrective Action
1
VT-100 cannot login
CIT cable connection invalid.
Baud Rate incorrect and com port
incorrectly selected.
Input wrong account and password
Check cable link
Check baud rate and com port
Check login name and password
2
The equipment screen alarm
indicators are different from
physical indicators.
Alarm configurations incorrectly set.
Physical alarm connector faulty.
Check Tributary Slot parameters and
Ethernet parameters configuration screen.
Check service mode
Check Ethernet port contacts
Check Ethernet cable
Check duplex matching
Disable unused ports
3
Ethernet has serious packet
loss.
RJ45 connector is damaged.
FUUL/HALF duplex does not Trunk
Ethernet port service.
Check the duplex matching.
Check the auto-neg mode.
Check data forwarding mode.
Check all Trunk Ethernet port configuration
functions.
4
Ping fails, can’t transfer data, or
can’t remote Telnet.
Trunk Ethernet port service is off.
fiber cable failure.
RJ45 connector is damaged.
Networking service management telnet
function is off.
Trunk Ethernet general parameters setting
error.
Check duplex matching.
Check all Trunk Ethernet port configuration
functions.
Check the fiber contacts.
Test and/or change optical cable
Check networking service management
function and preform loopback test.
Execute Autoblk to check optical
connection.
5
The unit is reset or powered off,
all the configuration settings are
lost.
User did not save configuration.
Incorrect loading profile was selected
during last startup.
The iMux will startup according to the last
startup profile loaded.
Select the correct startup profile on
startup.
If you loaded the factory default profile
during you last startup, the iMux will
default to the factory setting upon restart.
6
The iMux cannot be managed
Networking service management SNMP
function is turned off.
Device IP is incorrect.
SNMP agent configuration read/write
community is incorrect.
Check networking service management.
Check device IP.
Check SNMP agent configuration.
7
Power indicator is off
Power supply is not available.
The power supply switch is not turned on.
the power supply connections are loose or
faulty.
Change the power supply.
Turn on the iMux power switch.
Check all power connections.
116! Troubleshooting