User Manual

15 • Operation in Measuring Mode SC-01 Operators Manual
Table 3: Alarm Types and Indications
Alarm Type LCD Indications Other Indications
Warning
Concentration of gas
rises above the
Warning level.
Gas reading
flashes.
Back light turns on.
Pulsing tone
alternates with
alarm LEDs
flashing once per
second.
Unit vibrates once
per second.
Alarm
Concentration of gas
rises above the Alarm
level.
Gas reading
flashes.
Back light turns on.
Pulsing tone
alternates with
alarm LEDs
flashing twice per
second.
Unit vibrates twice
per second.
TWA or STEL
Concentration of
target gas rises above
the TWA or STEL
alarm point.
Back light turns on.
Gas reading
flashes.
TWA or STEL
replaces the gas
name in the upper
left of the LCD.
Pulsing tone
alternates with
alarm LEDs
flashing once per
second.
Unit vibrates once
per second.
Over Range
Concentration of gas
rises above the full
scale of the SC-01.
(Or there could be a
problem with the unit.)
Gas reading
replaced by blinking
brackets.
Back light turns on.
Gas name in upper
right of display
replaced by OVER.
Pulsing tone
alternates with
alarm LEDs
flashing twice per
second.
Unit vibrates twice
per second.
Low Battery Warning
Last remaining bar on
the right in battery icon
flashes.
None
Dead Battery Alarm Gas name and
reading replaced by
BATTERY FAIL.
Battery icon
flashes.
Quick pulsing tone
and LED flashing for a
few seconds
alternates with the unit
vibrating for one
second.