Oxygen Transmitter • 12 Pioneer Operator’s Manual (PRELIMINARY)
Channel type screen
This screen indicates the channel type for Channel 1. The default setting for the channel
type (input) setting for the oxygen transmitter is
4-20 Remote
.
To accept the setting and continue the program, press the ENTER button.
The program displays the Relay 3 Assignment screen.
To update the setting:
1. Use the UP/YES or DOWN/NO button to change the setting.
2. Press the ENTER button to accept the new setting and continue the program.
The program displays the Relay 3 Assignment screen.
Relay 3 assignment screen
This screen indicates the assignment of the alarm 3 relay for Channel 1. If you select
Alarm 3
, then the alarm 3 relay activates if Channel 1 goes into an alarm 3 condition.
If you select
Fail Alarm
, then the alarm 3 relay de-energizes if Channel 1 goes into a fail
condition.
NOTE:
If you assign the alarm 3 relay as the channels fail relay, the status light and
buzzer still indicate visual and audible alarms for an alarm 3 condition.
To accept the relay 3 assignment setting and continue the program, press the ENTER
button.
The program displays the Fail Setpoint screen.
To update the relay 3 assignment setting:
1. Use the UP/YES or DOWN/NO button to change the setting.
2. Press the ENTER button to accept the new setting and continue the program.
The program displays the Fail Setpoint screen.
INP
U
T:
4
-
2
0Remte
o
C
hannel
1
R
e
la
y
3
A
ss
ign
e
d
to
:
Al
a
rm
3