User Manual

Pioneer Operators Manual (PRELIMINARY) Combustible Gas Transmitter 23
8. Reconnect the wiring from the Pioneer to the interconnect terminal strip as shown in
Table 4 and Figure 3, Wiring the Combustible Gas Transmitter to the Pioneer Gas
Monitor.
9. Reconnect the detector leads to the interconnect terminal strip as shown in Table 5 and
Figure 3, Wiring the Combustible Gas Transmitter to the Pioneer Gas Monitor.
10. Place the Pioneers power switch in the ON position.
CAUTION: Allow the detector to warm up for 15 minutes before you continue with the next step.
11. Calibrate the combustible gas transmitter as described in the Calibration section of
this insert.
Table 4: Reconnecting the Combustible Gas Amplier to the Pioneer Gas Monitor
Amplier
Interconnect Terminal Strip
Pioneer Analyzer Card
GND Gnd (Terminal 7)
4-20 4-20 (Terminal 5)
24V 24 V (Terminal 6)
Table 5: Reconnecting the Combustible Gas Detector to the Amplier
Detector Lead
Amplier
Interconnect Terminal Strip
Red SENSOR RED
White SENSOR WHT
Green SENSOR GRN
Black SENSOR BLK