User Manual
Combustilbe Gas Transmitter • 14 Pioneer Operator’s Manual (PRELIMINARY)
Alarm 1 setpoint screen
This screen indicates the setpoint and alarm type for Alarm 1. The default setting for the
alarm 1 setpoint for the combustible gas channel is
10
. The default setting for the alarm
type is
RISE
.
• To accept the settings and continue the program, press the ENTER button two times.
The program displays the Alarm 2 Setpoint screen.
• To update the alarm 1 setpoint:
1. Use the UP/YES and DOWN/NO buttons to change the setpoint.
2. Press the ENTER button two times to accept the new setting and continue the
program.
The program displays the Alarm 2 Setpoint screen.
• To update the alarm type setting:
1. Press the ENTER button to select the alarm type setting. (The setting flashes when
it is selected.)
2. Use the UP/YES or DOWN/NO button to change the setting.
3. Press the ENTER button to accept the new setting and continue the program.
The program displays the Alarm 2 Setpoint screen.
Alarm 2 setpoint screen
This screen indicates the setpoint and alarm type for Alarm 2. The default setting for the
alarm 2 setpoint for the combustible gas channel is
20
. The default setting for the alarm
type is
RISE
.
• To accept the settings and continue the program, press the ENTER button two times.
The program displays the Alarm 3 Setpoint screen.
• To update the alarm 2 setpoint:
1. Use the UP/YES and DOWN/NO buttons to change the setpoint.
2. Press the ENTER button two times to accept the new setting and continue the
program.
The program displays the Alarm 3 Setpoint screen.
• To update the alarm type setting:
1. Press the ENTER button to select the alarm type setting. (The setting flashes when
it is selected.)
2. Use the UP/YES or DOWN/NO button to change the setting.
3. Press the ENTER button to accept the new setting and continue the program.
The program displays the Alarm 3 Setpoint screen.
C
h
annel 1 Alarm
1
0%
LEL
CO
MB
1
RI
S
E
C
h
annel 1 Alarm
2
0%
LEL
CO
MB
2
RI
S
E