Photo Ionization Detectors (DID)
MiniRAE Lite by RAE Systems
The MiniRAE Lite is the most reliable handheld volatile organic compound (VOC) monitor on the
market. Its photoionization detector’s (PID) range of 0 to 5,000 ppm makes it an ideal instrument
for applications ranging from environmental to construction.
The patented sensor provides the following unique features: »
- a 3-second response time
- extended range up to 5,000 ppm
- humidity compensation
Designed for service - Easy access to lamp and sensor in seconds without tools »
Big graphic display for easy overview of concentration »
Field-interchangeable battery pack, replacable in seconds without tools »
Integrated flashlight for better visibility in low light »
Multi-language support with 12 languages encoded »
Rugged housing withstands use in harsh environments »
Photo Ionization Detectors (PID)
Description
MiniRAE Lite
UltraRAE by RAE Systems
The UltraRAE is a quick, spot-check monitor typically used by occupational health, safety, and
environmental personnel. The combination filter tube and Photoionization Detector (PID) removes
the disadvantages associated with colorimetric tubes and gas chromatographs. The UltraRAE
has the advantage of providing a fast, continuous reading and datalogging of concentrations of
Benzene, Methylene Chloride, or Butadiene. Applications include tank entry pre-screening during
refinery and plant maintenance, hazardous material response, marine spill response, and refinery
down-stream monitoring.
The only compound specific monitor with combination of interchangeable separation tubes and PID »
3-10 times faster analysis compared to conventional tube or portable gas chromatograph methods: Results »
obtained in seconds rather than minutes; detects benzene down to 0.1 ppm in 60 seconds
Built-in Bar Code Reader allows easy switching between total VOCs and benzene-specific measurements »
3,000 point datalogging storage capacity for data download »
Excellent range and linearity: Good down to 0.1 ppm and up to over 200 ppm benzene (no more GC column over- »
load problems); more accurate than gas detection tubes
Internal pump allows you to sample deep (up to 30ft or 10m) into a confined space; prevents liquid flow into the »
monitor and warns if sample tubing is blocked or crimped
Inexpensive analysis using low cost RAE-SepTM tubes in place of gas detection tubes »
Cheaper than portable GC and no annual factory calibration »
Large keys are operable even with 3 layers of gloves »
Large easy-to-read back light display that is alarm-, darkness-, or manually-activated »
Optional vibration alarm »
Snap-in rechargeable or alkaline battery pack provides 10 hours of operation with smart battery charging »
Description